Oil & Gas Industry, Highly Customizable UPS AC & DC UPS Systems
Cathodic Protection Rectifier Systems
Rectifiers and Inverters
IEC 60529
IEC 62040-1, 2, 3
UL, CSA
UPS or Genset Capacity & Performance Testing
Datacenter Simulation
Marine or Military Applications Load Testing
TSINE Load Ultima Series Precise, Over-Engineered Systems and Solutions
IP Rated or Containerized Designs
RLC or DC Load Banks
TSINE LT9000 Series Three Phase UPS | Aa cutting-edge, highly efficient uninterruptible power supply
Dyna-Ion Series Lithium Battery Solution by tsinepower.
Standard 6000 cycles lifetime and 10000 cycles extended cell lifetime.
Containerized Power Systems
Marine, Telecom, Railways, Industrial & BESS - Micro-grid or Utility Operator Industries
Best-in-Class, Plug & Play Ready to Go Designs.
Mobile
Containerized
Centralized
Isolated
From Design Stages to On-Site Power Infrastructure
Experience The True Fail-Safe Features & Availability
The NetXtend Flex Online UPS presents high level of availability, true versatility, scalability and industry leading efficiency along with minimized CAPEX & OPEX mission-critical loads & systems in your power infrastructure.
The true modular topology with hot-synch/ hot-swap power modules design, three level highly-efficient power conversion, in which every module has its own processor DSP unit is inside and independent, all enables the UPS NetXtend Flex to secure & optimize the powerflow for both upstream and downstream paths.
NetXtend Flex gives the power of control to the user allowing to secure the power infrastructure via modular n+x redundancy that also can be used for load & capacity expansion for future requirements.
NetXtend Flex Online UPS, TSINE expertise behind and premium components inside, is engineered to meet
the needs of demanding environments & businesses worldwide.
Industrial interconnection converter architecture, the new generation of Static Frequency Converter (SFC) allows the connection of 60 Hz powered equipment to a 50 Hz supply network and 50 Hz powered equipment to a 60 Hz supply network.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
UPS Rating [Unity Power Factor, kVA=kW, pf.: 1] | Efficiency Levels | ||||||||||||||||||||||
Rated Power [kVA] | Available in 25 kVA – 1800 kVA | AC~AC Mode, On-line | Up To 97% at 100% Rated Load, 95.5% at 50% Rated Load | ||||||||||||||||||||
Power Cabinets [kVA] | 150 | 250 | 500 | 180 | 300 | 600 | Eco Mode | > 99% | |||||||||||||||
Power Modules [kVA] | 25 kVA/ 25 kW; P.f. 1 & 30 kVA/ 30 kW; P.f. 1 | Battery Mode | > 96% | ||||||||||||||||||||
System Controller & User Interface | Input Characteristics | ||||||||||||||||||||||
Display Type | 10.4” Touch Colour LCD, LED System Status Indicators & Keyboard | Rated Voltage & Range | 380/ 400/ 415 VAC 3P+N+G -24%~20% 304~478Vac full load; 228V~304Vac, within these tolerances, | ||||||||||||||||||||
Fail-Safe Design | In the event of a power module failure, the system will continue to operate uninterrupted. | the output load shall decrease l nearly as per the minimum utility voltage. | |||||||||||||||||||||
Each power module has its own redundant controlled and static bypass, | Rated Frequency & Range | 50/ 60 Hz, 40 ~ 70 Hz | |||||||||||||||||||||
Zero interruption to the load. | Power Factor | ≥ 0,99 Active Power Factor Correction Circuitry | |||||||||||||||||||||
Available Languages | 5 Standard – EN-TR-SP-FR-RU | Current Distortion [THDi] | < 3% @ Full Linear Load | ||||||||||||||||||||
Power Analyser | kVA, kW, PF Info | Power Walk-In | Between 1-30 seconds, with 1 s intervals | ||||||||||||||||||||
Real Time Clock | Standard with Dynamic Estimation of Back Up Period | ||||||||||||||||||||||
Event Log | 500 Events with Details & Info, Downloadable via USB-Ethernet | Battery | Back Up Power | |||||||||||||||||||||
Smart Event Notification & Scheduled Shutdown for Servers | Controlled Shutdown. Alerts sent directly to email in the event of a malfunction (Standard | Rated Voltage [DC] | ±240VDC, 32 to 44 * 12VDC (Adjustable) VRLA AGM Sealed Lead Acid, Ge | ||||||||||||||||||||
up to 10 users) Text message alerts sent directly to the user in the event of a malfunction (Optional) | DC Input Range | Final Discharge Voltage can be 1.65Vdc or 1.7Vdc | |||||||||||||||||||||
Scheduled Automatic Shutdown of Servers on Battery Mode (Standard) | Ai-BM | Manual & Scheduled Battery Test, Scheduled Automatic Shutdown of Servers on Battery Mode, | |||||||||||||||||||||
On-Screen Parameters | Load Bar-Graph, 3 Phase Voltages & Currents & Frequencies, Battery Voltage, Status Info for | (Optional) Real Time Dynamic Remaining Back Up Calculation, | |||||||||||||||||||||
Each Power Module, Static Bypass Module Parameters & Status Info, Battery Temperature | Modular Hot-Swap Battery | Optional | |||||||||||||||||||||
Alarms | AC Failure, DC Failure, UPS Module(s) Failure, Bypass Mode, Battery Test Failure, Over Temperature, | Charging Capacity | 6A for Each 20 kVA Module, 9A for Each 30 kVA Module | ||||||||||||||||||||
Overload Operation, More Than 60 Other Alarms Listed in User Manual, Audible Alarms | Operating Temperature | 25ºC, Temperature Compensated 4 Stage Charging | |||||||||||||||||||||
SNMP-Remote Montoring (MS Windows), TCP/IP, Monitoring Over Web Browser, Hot swappable | |||||||||||||||||||||||
Connectivity | smart slot card, RJ -45 interface port, USB, RS232, RS485, MODBUS, Optional GPRS/SMS Wireless, | Output Characteristics | |||||||||||||||||||||
Programmable Dry Contacts | Rated Voltage & Accuracy | 380/ 400/ 415 VAC 3P+N ± 1% for Static Load, for Dynamic Load (Step Load) : ± 5% | |||||||||||||||||||||
Communication with Power Modules | Serial, Isolated | Rated f. & Accuracy | 50/ 60 Hz (Selectable), ±1% ( Synchronized to Mains, Adjustable up to ±5%), | ||||||||||||||||||||
Dry Contacts | 3 Programmable Dry Contacts for Input, 11 pcs Parameters, 4 Programmable Dry Contacts for | ±0,1% ( Free Running Mode, Selectable) | |||||||||||||||||||||
Output, 15 pcs Parameters, 19 Dry Contacts, EPO Outputs in Total | WaveForm | Pure Sine Wave – Sinusoidal | |||||||||||||||||||||
Voltage Distortion [THDv] | < 1% (Linear Load), < 4% (Non-Linear Load) according to IEC/EN62040-3 | ||||||||||||||||||||||
General Characteristics | Crest Factor | 3:1 | |||||||||||||||||||||
MTBF/ MTTR | Over 600000 Hours | Unbalanced Load & Acceptable Load PF | Compatible with Operation on 100% Unbalanced Load 0.3 to 1 | ||||||||||||||||||||
UPS Type & Technology | VFI-SS-111 | Online Double Conversion, Three Level Technology | Overload Operation | 60 minutes @ 110% Rated Load, 10 minutes @ 125% Rated Load 1 minutes @ 150% Rated Load | ||||||||||||||||||||
DSP Microprocessor Controlled, Hot-Swap Modular Architecture | Switches to Bypass over 150% Rated Load | ||||||||||||||||||||||
Isolation Transformer | STANDARD For Flex-T Series | ||||||||||||||||||||||
62040-3 | COMPATIBLE | Ambient Characteristics | |||||||||||||||||||||
Power Factor | 0,9 or 1 kVA=kW Unity Power Factor | Ambient Temperature | OPERATING TEMPERATURE RANGE -10ºC – 40ºC | ||||||||||||||||||||
True Redundancy | N+X, N+1 Redundancy, True Modular UPS Topology | RECOMMENDED OPERATING TEMPERATURE 15ºC – 25ºC | |||||||||||||||||||||
Parallel Configuration [N+1] | Up to 3 Power Cabinets and 1800 Kw | STORAGE TEMPERATURE -30ºC ~ 70ºC | |||||||||||||||||||||
Input Power Limiting, Phase Reversal, Power Module Over Temperature, Over Current, | Altitute/ Relative Humidity | < 1000m above sea level without derating of output power, | |||||||||||||||||||||
Standard Protection Features | High Temperature Alert, Smart Short Circuit, Regenerative Load, Current Limiting, Charging Current | output power is derated 1% per 100m from 1000 to 2000m | |||||||||||||||||||||
Limiting, Temperature Compensated Charging, Emergency Power Off (EPO). | Noise | < 65dB @ 100% load, 62dB @ 45% load | |||||||||||||||||||||
Operating Conditions | 20 ºC, <2400m Above Sea Level, <45% to 55% RH for Best Performance | ||||||||||||||||||||||
Cooling/ Isolation | Forced Air Cooling via Redundant Fans – Smart Fan Speed | Standards & Certifications | |||||||||||||||||||||
Ma ntenance Bypass | STANDARD | Safety | EN 62040-1, EN60950, CE Mark | ||||||||||||||||||||
Material [Casing]/ Colour | RAL 7021, BLACK | EMC | EN 62040-2 Class C2, CE Mark – Electro-magnetic Compability | ||||||||||||||||||||
Cable Entry | REAR/ FRONT BOTTOM | Performance | EN 62040-3 (VFI-SS111), CE Mark | ||||||||||||||||||||
Operation Modes | Normal Mode: The input rectifier & output inverter operates in an on-line status to continuously supply power to the critical load. | Quality Management | ISO 9001:2015, TUV, CE Mark | ||||||||||||||||||||
Battery Mode: Upon failure of the AC input source, the critical load is being continued to be supplied by the inverter, which derives its power from the battery system without any interruption. | |||||||||||||||||||||||
Recharge: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load. | Optional Features & Accessories | ||||||||||||||||||||||
Static Bypass: The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source. | Parallel Redundancy | Horizantal Power Scaling, Optional | |||||||||||||||||||||
Internal Manual/ Mechanical Bypass: The UPS is equipped with an internal, make before break, bypass switch. | Hot-Swappable Battery | Optional | |||||||||||||||||||||
Extended Runtime | Optional | ||||||||||||||||||||||
M. Bypass Cab net | Optional | ||||||||||||||||||||||
Custom Input Voltage | Optional | ||||||||||||||||||||||
IP Classified Enclosure | Standard IP21, Optional up to IP 66 | ||||||||||||||||||||||
Tab Content
Online, three level, the best in class AC/AC efficiency levels as 99% in ECO mode.
The flat efficiency curve from 35 % of load ensures maximum energy savings at every percentage of load.
Modular, hot-swappable power modules concept, Scalable.
Power modules has independent hardware and controllability,
Control of power modules decentralized, individual (no centralized control system).
Robust & reliable operation, maximum avaiability and uptime for the systems
& loads connected to the ups.
Service-friendly design ensures rapid and easy maintenance and minimizes service costs
Automated load distribution within all system modules enables a modular n+x redundancy,
Eliminated single point of failures in even power module base.
Superior MTBF & MTTR values.
High power density, minimised footprint, vertical and horizantal capacity expansion.
Superior connectivity standards, global monitoring,quicker recovery.
Warranty | 6 months |
---|---|