Aviation Power, GPU | ProXtend GP

The Ground Power Units, GPU, by tsinepower

The ProXtend GP Series Ground Power Units supplies pure, clean and continuous (S1) isolated sinewave power from the upstream sources to the advanced aircraft systems in commercial, private or military aviation industries.

ProXtend GP is designed for the aviation industry and aircrafts requiring external power supply when they are in parking position or for maintenance/ repair works in hangars.

ProXtend GP delivers the 400Hz @115/208V L-L external supply to the aircrafts via hard wired terminals or 6 pin connectors with 28V safety interlock while the input can be dual or triple different voltage levels.

ProXtend GP is having transformer at its input which isolates all the mains fluctuations, noise from the output, where the aircraft supply is connected. Due to the transformer based low frequency or transformer supported IGBT Rectifier high frequency design, the ProXtend GP is robust with high inrush current capacity, high overload capacities.

The ProXtend GP can be used in civil or military aviation and can be connected to F16 or F22 raptor or Sikorsky type aircrafts, even compatible with Europe and Korea made aircrafts.

It also delivers the requested customization with 7” TFT Touchscreen display or ON-OFF-STOP-START-ESC button type user interface and advanced and wired or wireless connectivity features.

TSINE addresses reliability, trouble-free cutting-edge technologies for advanced industries with its vast engineering experience.

Pro-IT Isolation Transformers, up to 600V, 5 VA to 4000 kVA

Best Suited for

Facilities, Mixed Loads Use

Industrial Loads & Systems

Medium & Large Sized Enterprises

Healthcare Facilities, Diagnostics and Medical Imaging Systems, CTs, MRIs, Angiography Devices

Financial Institutions, Banks, Banks Headquarters

Buildings of Government, Institutions & Organizations

Airports, Military & Police Stations

Tunnels, Automation & Ventilation Systems

Description

High AC~AC efficiency levels up to 94.5%

High battery conversion, inverter efficiency as 96.5%

Zero Effect on Utility with Active Power Factor Correction at Input, pf is ≥ 0.99

Low total harmonic distortion for input current as ≤ 4%

Compatible with the toughest application requirements with its super efficient IGBT Rectifier without sacraficing reliability.

Fault tolerant design allows the UPS both protect the connected load and itself from mechanical & electrical forces.

Robust, easy to operate UPS has excellent overload and short circuit capability, superior dynamic response and is easy to maintain.

Compact, easy and ready to install dimensions, minimized footprint, ease to move & locate inside buildings,

160 kVA footprint is only 0,87 m2 (Module IGBT rectifier and inverter), Maximum single unit capacity is 800 kVA in 1,74 m2

Up to 40 kVA, Inbuilt batteries saves from space.

The UPS ProXtend HE is designed for maximized availability and uptime.

Minimized Service and Repair Times, Maximum Time to Repair, MTTR;  Maximized Mean Time Between Failures, MTBF, times

Since a datacenter’ s availability is scaled as 99.99%, Our UPS Systems offers the similar.

Thanks to Lower THDi and Active PFC at Input Side, Cost savings on Low Voltage Installation in UpStream The UPS

Reduced installation and operation costs, minimized footprint, minimized UPS/Electrical Room Requirements.

Operational expenditure is optimized with a complete and cost effective life cycle.

The high efficiency of the complete UPS (AC/AC), as well as of the inverter part (DC/AC), even at partial load, helps optimizing both HVAC system and battery sizing.

Less maintenance needs, advanced battery management which leads extended battery lifetime and extended lifetimes for lifed items means long replacement times and avoiding repeating costs.

 

The Result: Reduced Total Cost of Ownership & Fast Return of Investment

Thanks to Max. Availability and Max. Uptime for The Businesses, Minimized Downtimes.



Features

Easy & Fast Serviceability, Fast Dynamic Solutions to On-Site Problems

Robust, Reliable Operation, Proven Track Record and Use

Compact, highly-efficient, cutting-edge technology with built-in features to adapt to diverse environments and requirements.

IGBT Rectifier/ IGBT Inverter, Double Conversion Architecture, Available with Various Global Voltages

Seamless transfer between sources, high generator compability

High efficiency rates as up to 94%, even at partial load

Small footprint, high power density

Fault-tolerant, over-engineered design, DSP ultra high speed control architecture

High output short-circuit clearance capability

High output short-circuit clearance capability

Prolonged battery lifetime, budget -friendly lifetime.

Reliable Redundant parallel operation

High communication and connectivity capabilities

Options for Enclosure IP Classifications, Isolation Transformers,

Additional information

Voltage Class

600V

Input Voltage

, , , , ,

Output Voltage

, , , ,

Ratings

50W – 500 kVA

Voltage & Frequency

208-220-380- 400-440-480- 600Vac Others on Request

Windings Material

Copper or Aluminum

Efficiency

97% or higher

Form Factor

, ,

Transformer Design

Delta/Star, without neutral at the input

Neutral Line Capacity

100% of nominal

Dielectric Strength

4,2kVac min

CMNA

146 dB (with triple shielding)

Overload Capacity

200% for 30 sec, 500% for 1 sec,
1000% for 1 cycle

Load Regulation

±1% at full load.

Audible noise

< 45 dB at 1mt.

Enclosure type

IP21, metal, epoxy painted RAL7035

Operating temperature

0°C to 50°C ambient

Operating humidity

up to 90% relative (non condensing)

Operating altitude

up to 1000mt above sea level

ProXtend HP EU Product Datasheet