STS Solutions
Dual Source
Multi-Source
Zero Transfer
Priority Selection
Advanced Custom Features and Connectivity
Oil & Gas Industry, Highly Customizable UPS AC & DC UPS Systems
Cathodic Protection Rectifier Systems
Rectifiers and Inverters
IEC 60529
IEC 62040-1, 2, 3
UL, CSA
UPS or Genset Capacity & Performance Testing
Datacenter Simulation
Marine or Military Applications Load Testing
TSINE Load Ultima Series Precise, Over-Engineered Systems and Solutions
IP Rated or Containerized Designs
RLC or DC Load Banks
TSINE LT9000 Series Three Phase UPS | Aa cutting-edge, highly efficient uninterruptible power supply
Dyna-Ion Series Lithium Battery Solution by tsinepower.
Standard 6000 cycles lifetime and 10000 cycles extended cell lifetime.
Containerized Power Systems
Marine, Telecom, Railways, Industrial & BESS - Micro-grid or Utility Operator Industries
Best-in-Class, Plug & Play Ready to Go Designs.
Mobile
Containerized
Centralized
Isolated
Continuous Duty STS Solutions
The PowerSelect STS is cutting edge static transfer system from TSINE Electronics which ensure high level of power availability when the main source becomes unavailable. Static transfer switches by TSINE is DSP microprocessor controlled, when the power outage occurs or when the power is not within the predefined range in terms or voltage and frequency, The PowerSelect STS system, AC/AC Solid State transfer device, smoothly transfer power between two or more inputs using SCR or IGBT Technology seamlessly in less than 5 milliseconds which is a quarter of a period to the load.
Thus leads enhancing resilience and prevention fault propagation.
The PowerSelect STS also provides manual transfer via maintenance bypass switch.
The PowerSelect STS presents ultimate performance, highest availability, maximum robustness & versatility.
TSINE Electronics Industries is the center of design in power electronics in Turkiye & powering a vast range of businesses worldwide.
Main Features
SCR (Thyristor) or IGBT Design
DSP Controlled
Maintenance Bypass
Two or More Sources Design
Fail-Safe, Maximized MTBF
Best Suited for
Industrial interconnection converter architecture, the new generation of Static Frequency Converter (SFC) allows the connection of 60 Hz powered equipment to a 50 Hz supply network and 50 Hz powered equipment to a 60 Hz supply network.
Lorem ipsum dolor sit amet, consectetur adipiscing elit. Ut elit tellus, luctus nec ullamcorper mattis, pulvinar dapibus leo.
UPS Rating [Unity Power Factor, kVA=kW, pf.: 1] | Efficiency Levels | ||||||||||||||||||||||
Rated Power [kVA] | Available in 25 kVA – 1800 kVA | AC~AC Mode, On-line | Up To 97% at 100% Rated Load, 95.5% at 50% Rated Load | ||||||||||||||||||||
Power Cabinets [kVA] | 150 | 250 | 500 | 180 | 300 | 600 | Eco Mode | > 99% | |||||||||||||||
Power Modules [kVA] | 25 kVA/ 25 kW; P.f. 1 & 30 kVA/ 30 kW; P.f. 1 | Battery Mode | > 96% | ||||||||||||||||||||
System Controller & User Interface | Input Characteristics | ||||||||||||||||||||||
Display Type | 10.4” Touch Colour LCD, LED System Status Indicators & Keyboard | Rated Voltage & Range | 380/ 400/ 415 VAC 3P+N+G -24%~20% 304~478Vac full load; 228V~304Vac, within these tolerances, | ||||||||||||||||||||
Fail-Safe Design | In the event of a power module failure, the system will continue to operate uninterrupted. | the output load shall decrease l nearly as per the minimum utility voltage. | |||||||||||||||||||||
Each power module has its own redundant controlled and static bypass, | Rated Frequency & Range | 50/ 60 Hz, 40 ~ 70 Hz | |||||||||||||||||||||
Zero interruption to the load. | Power Factor | ≥ 0,99 Active Power Factor Correction Circuitry | |||||||||||||||||||||
Available Languages | 5 Standard – EN-TR-SP-FR-RU | Current Distortion [THDi] | < 3% @ Full Linear Load | ||||||||||||||||||||
Power Analyser | kVA, kW, PF Info | Power Walk-In | Between 1-30 seconds, with 1 s intervals | ||||||||||||||||||||
Real Time Clock | Standard with Dynamic Estimation of Back Up Period | ||||||||||||||||||||||
Event Log | 500 Events with Details & Info, Downloadable via USB-Ethernet | Battery | Back Up Power | |||||||||||||||||||||
Smart Event Notification & Scheduled Shutdown for Servers | Controlled Shutdown. Alerts sent directly to email in the event of a malfunction (Standard | Rated Voltage [DC] | ±240VDC, 32 to 44 * 12VDC (Adjustable) VRLA AGM Sealed Lead Acid, Ge | ||||||||||||||||||||
up to 10 users) Text message alerts sent directly to the user in the event of a malfunction (Optional) | DC Input Range | Final Discharge Voltage can be 1.65Vdc or 1.7Vdc | |||||||||||||||||||||
Scheduled Automatic Shutdown of Servers on Battery Mode (Standard) | Ai-BM | Manual & Scheduled Battery Test, Scheduled Automatic Shutdown of Servers on Battery Mode, | |||||||||||||||||||||
On-Screen Parameters | Load Bar-Graph, 3 Phase Voltages & Currents & Frequencies, Battery Voltage, Status Info for | (Optional) Real Time Dynamic Remaining Back Up Calculation, | |||||||||||||||||||||
Each Power Module, Static Bypass Module Parameters & Status Info, Battery Temperature | Modular Hot-Swap Battery | Optional | |||||||||||||||||||||
Alarms | AC Failure, DC Failure, UPS Module(s) Failure, Bypass Mode, Battery Test Failure, Over Temperature, | Charging Capacity | 6A for Each 20 kVA Module, 9A for Each 30 kVA Module | ||||||||||||||||||||
Overload Operation, More Than 60 Other Alarms Listed in User Manual, Audible Alarms | Operating Temperature | 25ºC, Temperature Compensated 4 Stage Charging | |||||||||||||||||||||
SNMP-Remote Montoring (MS Windows), TCP/IP, Monitoring Over Web Browser, Hot swappable | |||||||||||||||||||||||
Connectivity | smart slot card, RJ -45 interface port, USB, RS232, RS485, MODBUS, Optional GPRS/SMS Wireless, | Output Characteristics | |||||||||||||||||||||
Programmable Dry Contacts | Rated Voltage & Accuracy | 380/ 400/ 415 VAC 3P+N ± 1% for Static Load, for Dynamic Load (Step Load) : ± 5% | |||||||||||||||||||||
Communication with Power Modules | Serial, Isolated | Rated f. & Accuracy | 50/ 60 Hz (Selectable), ±1% ( Synchronized to Mains, Adjustable up to ±5%), | ||||||||||||||||||||
Dry Contacts | 3 Programmable Dry Contacts for Input, 11 pcs Parameters, 4 Programmable Dry Contacts for | ±0,1% ( Free Running Mode, Selectable) | |||||||||||||||||||||
Output, 15 pcs Parameters, 19 Dry Contacts, EPO Outputs in Total | WaveForm | Pure Sine Wave – Sinusoidal | |||||||||||||||||||||
Voltage Distortion [THDv] | < 1% (Linear Load), < 4% (Non-Linear Load) according to IEC/EN62040-3 | ||||||||||||||||||||||
General Characteristics | Crest Factor | 3:1 | |||||||||||||||||||||
MTBF/ MTTR | Over 600000 Hours | Unbalanced Load & Acceptable Load PF | Compatible with Operation on 100% Unbalanced Load 0.3 to 1 | ||||||||||||||||||||
UPS Type & Technology | VFI-SS-111 | Online Double Conversion, Three Level Technology | Overload Operation | 60 minutes @ 110% Rated Load, 10 minutes @ 125% Rated Load 1 minutes @ 150% Rated Load | ||||||||||||||||||||
DSP Microprocessor Controlled, Hot-Swap Modular Architecture | Switches to Bypass over 150% Rated Load | ||||||||||||||||||||||
Isolation Transformer | STANDARD For Flex-T Series | ||||||||||||||||||||||
62040-3 | COMPATIBLE | Ambient Characteristics | |||||||||||||||||||||
Power Factor | 0,9 or 1 kVA=kW Unity Power Factor | Ambient Temperature | OPERATING TEMPERATURE RANGE -10ºC – 40ºC | ||||||||||||||||||||
True Redundancy | N+X, N+1 Redundancy, True Modular UPS Topology | RECOMMENDED OPERATING TEMPERATURE 15ºC – 25ºC | |||||||||||||||||||||
Parallel Configuration [N+1] | Up to 3 Power Cabinets and 1800 Kw | STORAGE TEMPERATURE -30ºC ~ 70ºC | |||||||||||||||||||||
Input Power Limiting, Phase Reversal, Power Module Over Temperature, Over Current, | Altitute/ Relative Humidity | < 1000m above sea level without derating of output power, | |||||||||||||||||||||
Standard Protection Features | High Temperature Alert, Smart Short Circuit, Regenerative Load, Current Limiting, Charging Current | output power is derated 1% per 100m from 1000 to 2000m | |||||||||||||||||||||
Limiting, Temperature Compensated Charging, Emergency Power Off (EPO). | Noise | < 65dB @ 100% load, 62dB @ 45% load | |||||||||||||||||||||
Operating Conditions | 20 ºC, <2400m Above Sea Level, <45% to 55% RH for Best Performance | ||||||||||||||||||||||
Cooling/ Isolation | Forced Air Cooling via Redundant Fans – Smart Fan Speed | Standards & Certifications | |||||||||||||||||||||
Ma ntenance Bypass | STANDARD | Safety | EN 62040-1, EN60950, CE Mark | ||||||||||||||||||||
Material [Casing]/ Colour | RAL 7021, BLACK | EMC | EN 62040-2 Class C2, CE Mark – Electro-magnetic Compability | ||||||||||||||||||||
Cable Entry | REAR/ FRONT BOTTOM | Performance | EN 62040-3 (VFI-SS111), CE Mark | ||||||||||||||||||||
Operation Modes | Normal Mode: The input rectifier & output inverter operates in an on-line status to continuously supply power to the critical load. | Quality Management | ISO 9001:2015, TUV, CE Mark | ||||||||||||||||||||
Battery Mode: Upon failure of the AC input source, the critical load is being continued to be supplied by the inverter, which derives its power from the battery system without any interruption. | |||||||||||||||||||||||
Recharge: Upon restoration of the AC input source, the UPS simultaneously recharges the battery and provides regulated power to the critical load. | Optional Features & Accessories | ||||||||||||||||||||||
Static Bypass: The static bypass shall be used to provide transfer of critical load from the Inverter output to the bypass source. | Parallel Redundancy | Horizantal Power Scaling, Optional | |||||||||||||||||||||
Internal Manual/ Mechanical Bypass: The UPS is equipped with an internal, make before break, bypass switch. | Hot-Swappable Battery | Optional | |||||||||||||||||||||
Extended Runtime | Optional | ||||||||||||||||||||||
M. Bypass Cab net | Optional | ||||||||||||||||||||||
Custom Input Voltage | Optional | ||||||||||||||||||||||
IP Classified Enclosure | Standard IP21, Optional up to IP 66 | ||||||||||||||||||||||
Tab Content
Online, three level, highly-efficient design, efficiency is up to 94.5%
True discrete architecture for power modules
Superior MTBF & MTTR values, maximum availability and uptime for the systems & loads connected to the ups, great serviceability.
Built-in isolation transformer, more electrical & mechanical robustness.
Intelligent battery management, extended battery lifetime, flexible DC bus.
Robust & reliable operation at very high temperatures, harshest environments, challenging environments and loads
True and dynamic R&D, custom designs and device variations for the applications & systems in the field.
Robust & reliable operation at very high temperatures, harshest environments, challenging environments and loads
Superior connectivity standards, LCD display, user & service friendly LCD navigation and menus.